Hybrid/EV Battery Cell Balancing Circuit D
P0DB8 is the circuit code for balancing channel D. Here the controller sees a hardware problem: the switch, resistor or cell tap of group D reports a state that cannot be valid, typically an open lead or a short to a neighbouring line. Toshiba's patent US20130026994A1 shows how a monitoring chip can tell which balancing terminal is open and pass that to the main controller, which then decides whether the module or the cell unit must be repaired. CARB 13 CCR 1968.2 calls for this monitoring on hybrids. Audi's bulletin 2046556 names P0DB800 for the 2016 A3 e-tron, where the car could also wrongly report a plugged-in charger; new software cured it.
Possible causes
- Open balancing terminal or lead in group D high
- Short between neighbouring sense/balancing lines medium
- Monitoring chip of group D defective low
Symptoms
- MIL and battery system message
- Possible limitation of electric power
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DB8
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?