P0DB6
Hybrid/EV Battery Cell Balancing Circuit C Stuck Off
P0DB6 says that the bleed function of group C does not respond: commanded on, circuit C stays dead. In LG Chem's US20110285539A1 such a case shows up because a test capacitor charged to cell voltage is not emptied through the balancing path and keeps a high residual voltage. Typical culprits are an open resistor, a transistor that no longer conducts or a broken cell tap. While driving there is little to feel; the effect is that group C cannot be trimmed, so the strongest cell there caps every full charge. CARB 13 CCR 1968.2 demands detection of this. Ford documents P0DB6 in the 2018 OBD summary for its hybrids, one of fourteen balancing circuits there; a 75 mV spread inside the six-cell group, seen on two consecutive power cycles before the contactors close, triggers it.
Possible causes
- Bleed resistor of circuit C open high
- Balancing transistor of circuit C not conducting medium
- Broken cell tap or weld in group C low
Symptoms
- MIL with battery warning
- Shorter charging sessions and lower usable capacity
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DB6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?