P0DB2
Hybrid/EV Battery Cell Balancing Circuit B Stuck Off
Stuck off on circuit B (P0DB2) is the passive failure: the command arrives, but the bleed resistor of that group carries no current, so its high cells are never trimmed. LG Chem's patent EP2730933A1 tests for this by switching the balancing circuit on and off and watching how the voltage across a diagnosis resistor reacts; no change means a dead circuit. The result builds up over many charges: cells of group B reach the upper limit first and end charging early, while the rest stay below. CARB 13 CCR 1968.2 counts this as a balancing malfunction. Ford lists P0DB2 in its 2016 hybrid OBD summary: the BECM bleeds only the highest cells down to the others and judges each six-cell circuit once per power-up against a 75 mV limit. Compare P0DB1 for the opposite fault.
Possible causes
- Bleed resistor of group B burnt open high
- Balancing transistor of circuit B no longer switching medium
- Open terminal or cell tap connection in group B low
Symptoms
- MIL and battery warning
- Charging stops before the expected state of charge
- High cell voltages in group B in live data
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DB2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.