P0DAE
Hybrid/EV Battery Cell Balancing Circuit A Stuck Off
With P0DAE the controller has commanded balancing on circuit A, yet nothing happens: the switch stays open or the bleed resistor is broken, so the targeted cells keep their charge. Ford documents the code for its hybrid BECM; in the 2014 OBD summary the verdict rests on a 100 ms check at power-up with open contactors, in which one cell of the six-cell group lying beyond 75 mV from the average on two successive starts is enough. For a related code, GM checks on eAssist with the ignition off that the cell moves by more than 0.1 V once the resistor is switched in. The penalty is slow: the high cells limit charging, the pack loses usable capacity and the overall verdict P0DAB may follow.
Possible causes
- Bleed resistor of circuit A open or its solder joint cracked high
- Balancing transistor failed open medium
- Broken balancing/sense lead or terminal between module and cells medium
Symptoms
- MIL and battery system warning
- Charging ends early because individual cells reach full first
- Growing cell voltage spread in the live data
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0DAE
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.