P0D8F
Battery Charger A Cooling System Performance
P0D8F means the cooling of on-board charger A is not keeping the unit within its temperature limits, so the charger has to restrict its function. Mercedes documents the code with failure type 97 for the AMG GLE 53 Hybrid (bulletin LI47.70-P-079963, 2025): AC charging stops after about 15 minutes, the cluster reports AC charging inoperative and severely limited hybrid performance, and alongside P0D8F the charger stores an implausibility between its two coolant temperature sensors. The cause was the low-temperature circuits of power electronics and charger with swapped coolant lines; the remedy is to exchange them, not the charger. Air-cooled chargers, such as in Ford's older plug-in hybrids, report overheating under P0D24 instead. Charger B uses P2DB6.
Possible causes
- Low coolant level or air in the charger's cooling circuit high
- Coolant lines connected to the wrong circuit (Mercedes AMG GLE 53 Hybrid) medium
- Failed coolant pump of the low-temperature circuit medium
- Blocked low-temperature radiator or inactive cooling fan low
Symptoms
- AC charging stops after a short time or runs at reduced power
- Warning that AC charging is inoperative
- Hybrid drive performance limited
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0D8F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?