P0D7A
A/C Compressor Motor Phase U Current Low
Electric A/C compressors run a three-phase motor whose phase currents U, V and W are measured inside the inverter. P0D7A belongs to phase U. GM's 2011–2015 Volt and 2016 ELR test the sensors while the motor is stopped and the speed request is zero, when no current should flow: a phase U reading of +68 A or more in 30 of 60 samples at 50 ms sets P0D7A, Type B with MIL after two trips, and a 12 V reset is needed before it can pass again. In other words, GM uses the code for a current-sensor offset at standstill rather than for weak current during operation. The cause lies in the inverter's current sensing; the compressor normally stops. The negative counterpart is P0D7B, other phases P0D7C and P0D7E.
Possible causes
- Offset or failure of the phase U current sensor in the inverter high
- Fault in the inverter's current measuring circuit medium
Symptoms
- Check engine light after two trips
- Air conditioning does not start
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended