Powertrain
generic / SAE
P0D68
A/C Compressor Motor Voltage Sensor A Circuit
The voltage sensor A of the electric A/C compressor motor reports a generic fault. Compressor voltage feedback unreliable.
SystemPowertrain
Typegeneric / SAE
GroupP0
Range / numberD / 68
Possible causes
- Voltage sensor failed high
- Wiring fault medium
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 200–1200 €
- Estimated time: 1–4 h
- Component: ac compressor motor voltage sensor a
- Component: wiring harness
- Component: ac compressor module
- MIL / check engine light
- limp mode possible
Sources
References
sae:J2012