P0D5E
Battery Charger Hybrid/EV System Discharge Time Too Long
P0D5E means the high-voltage side of the charger did not drop to a safe level in time after it was disconnected. GM's 2011 Volt charger module fails the test if 60 V or more remain 1.5 s after the discharge command, or 6.75 s after a confirmed communication loss with the hybrid controller; a backup routine then checks for battery current that would reveal a stuck contactor. The 2016 Volt allows 4 s after the contactors open, the 2019 Volt also 4 s against 58 V and adds a case for a failed voltage sensor combined with a stuck negative contactor. All are Type A with immediate MIL. A patent for on-board charger discharge circuits cites roughly 60 V as the safety limit. The opposite fault is P0D5D.
Possible causes
- Active discharge circuit of the charger not working high
- High-voltage contactor stuck closed keeps the bus energised medium
- Lost communication between charger and hybrid controller low
- Charger voltage sensor reads falsely high low
Symptoms
- MIL on (GM)
- Charging blocked after the fault
- Further high-voltage codes such as contactor faults may be stored
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D5E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.