P0D5B
Battery Charger 14 Volt Output Power Performance
P0D5B checks whether the power leaving the charger's built-in 14 V output is physically possible. GM's charger module for the Volt and ELR multiplies the measured 14 V output voltage and current and compares the product with the AC input power times a factor of about 2 plus an offset: 2.5 W in the 2011 table, 125 W in the 2014 Volt/ELR and 2016 ELR tables. Exceeding that for 1.6 s within a 2 s window sets a Type A fault with MIL. The test only runs when the sensor codes P0D44, P0D45, P0D49 and P0D4A are clear, and the same low-voltage power also enters GM's total output check P1ECE. Because the 12 V side only takes part while charging, failures mostly show up as charging faults.
Possible causes
- Voltage or current measurement of the 14 V stage reads too high high
- AC input power measured too low medium
- Low-voltage stage of the on-board charger faulty medium
Symptoms
- MIL on (GM)
- Charging interrupted
- 12 V battery not supported while plugged in
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D5B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.