P0D59
Proximity Detection Circuit A High
P0D59 is logged when proximity circuit A shows a voltage above its expected resting level at a moment when the charge port must be empty. GM's Volt uses the same plausibility window as for P0D58 but trips above 4.8 V: in 2011 with the door shut or above 12.4 mph in a range other than Park, from 2016 at more than 20 km/h outside Park, over 30 of 50 or 240 of 400 samples; the fault is Type A and turns on the MIL. Mercedes defines P0D5900 for the 22 kW charger of the third-generation smart electric drive as a short to positive in the plug contact sensing, and the same bulletin blames loose charger connectors for charging and start-up problems. Electrically, a short to a supply line or a broken reference path can raise the level.
Possible causes
- Proximity signal wire shorted to a supply voltage high
- Interrupted ground or reference path of the detection circuit medium
- Loose connector at the charger or charge inlet medium
Symptoms
- MIL on (GM)
- Inserted charging plug not recognised, no charging
- Start-up problems after charging (smart)
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0D59
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.