P0D52
Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Range/Performance
P0D52 flags an output current reading that lies inside the sensor's range yet cannot be right. Mitsubishi documents the check for the 2022 Outlander PHEV as a zero-point test: while the PHEV-ECU has not granted charging, no current should leave the charger, so an absolute reading of 1.5 A or more lasting 1 s sets the code; charging is halted and the charger/DC-DC unit is replaced. Kia includes P0D52 in bulletin 298 for the 2023 Niro EV, where the active code calls for replacing the integrated charging unit (ICCU). GM's Volt does not use P0D52 and instead judges current plausibility through its power balance P0D5C. Electrical out-of-range faults are P0D53 and P0D54; the circuit code is P0D51.
Possible causes
- Zero point of the output current sensor has drifted high
- Charger or integrated charging unit (Kia ICCU) failed high
- Outdated charger software low
Symptoms
- Poor or no AC charging
- MIL or electric system warning (Kia)
- DC fast charging may still work (Kia)
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D52
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.