P0D51
Battery Charger Hybrid/EV Battery Output Current Sensor Circuit
P0D51 covers a circuit fault of the sensor that measures the direct current the on-board charger pushes into the traction battery. No manufacturer documents P0D51 itself. GM's charger module for the Volt and ELR and Mitsubishi's Outlander PHEV use the low and high codes P0D53 and P0D54 for electrical faults of this sensor, and Mitsubishi adds P0D52 for an offset check. Without a usable current value the charger can neither regulate charging current nor prove that its output power matches its input, a check GM performs under P0D5C. CARB obliges plug-in hybrids to detect charger malfunctions that prevent or slow charging. Expect AC charging to be blocked while the vehicle itself keeps driving.
Possible causes
- Current sensor or its evaluation circuit in the charger failed high
- Open signal path between sensor and charger controller medium
- Charger software fault low
Symptoms
- AC charging does not start
- Charging system warning shown
- Driving not affected
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D51
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.