P0D4E
Battery Charger Hybrid/EV Battery Output Voltage Sensor Circuit Low
P0D4E reports a signal below the valid range for the sensor measuring the charger's DC output toward the traction battery. In GM's charger module for the 2011-2014 Volt and ELR the raw value must stay at or below 2.62 V for 400 of 500 ms; the fault is Type A and lights the MIL at once. The 2016-2019 Volt reads the sensor as a duty cycle and treats 8 % or less, or a signal stuck at 100 %, as low, Type B. Mitsubishi's 2022 Outlander PHEV calls it a short to ground: under 0.943 V, equal to about -7 V, for 0.5 s; charging is stopped and the charger/DC-DC unit is replaced. GM's Bolt EI PIE0828 also lists the code. Its counterpart is P0D4F; plausibility errors fall under P0D4D.
Possible causes
- Voltage sensor signal shorted to ground inside the charger high
- On-board charger (Mitsubishi charger/DC-DC unit) failed high
- Internal reference supply of the measuring circuit missing low
Symptoms
- Charging stops or does not start
- MIL on (GM)
- Charging fault message
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D4E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.