P0D4A
Battery Charger 14 Volt Output Current Sensor Circuit High
P0D4A sets when the current sensor in the charger's 14 V output reports 54 A or more. GM's battery charger control module in the 2011-2014 Volt and the ELR applies that threshold for 400 of 500 ms with the low-voltage section awake and treats the result as a Type A fault with MIL. Either the sensor signal is stuck high or the output is genuinely overloaded or shorted; GM's tables do not separate the two. P0D49 is the low counterpart, and both block GM's 14 V output power check P0D5B. Because the stage sits inside the on-board charger, the car's main DC/DC converter is not the place to look. Owners mainly notice that the car refuses to charge or stops charging soon after plugging in.
Possible causes
- Current sense signal stuck high inside the charger high
- Overload or short on the charger's low-voltage output medium
- Failed on-board charger medium
Symptoms
- Vehicle will not charge
- MIL on (GM)
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D4A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.