P0D49
Battery Charger 14 Volt Output Current Sensor Circuit Low
P0D49 reports that the current sensor in the charger's 14 V output reads too low. GM's battery charger control module in the 2011-2014 Volt and the ELR sets it when the raw current value is 0.293 A or less for 400 of 500 ms while the low-voltage section is awake, as a Type A fault with MIL; the 2016 ELR charger table also lists it as a precondition for its output power checks. GM treats a value at this level as a sensor fault, which points to an open or grounded sense path or failed measuring electronics. The high counterpart is P0D4A. This output is a low-voltage stage inside the charger, not the Volt's separate accessory power module. Charging behaviour can be affected; driving normally is not.
Possible causes
- Open or grounded current sense path inside the charger high
- Failed low-voltage stage of the on-board charger medium
- 12 V supply or fuse of the charger interrupted low
Symptoms
- MIL on (GM)
- Charging may fail
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D49
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.