P0D45
Battery Charger 14 Volt Output Voltage Sensor Circuit High
P0D45 is stored when the charger's 14 V output voltage sensor reads too high. GM's battery charger control module in the Volt and ELR fails it at a reading of 16.88 V or above for 400 of 500 ms; the 2011 table rates it Type A, the 2014 table Type B, meaning the MIL comes on only after two consecutive trips. That value lies above the normal regulation band of a 12 V system, so either a genuine overvoltage at the output or a sensor reading stuck high is possible. The low counterpart is P0D44, and the plausibility check P0D43 pauses while either code is active. As with its siblings, the fault sits in the charger's own low-voltage stage rather than in the car's main DC/DC converter.
Possible causes
- Voltage sense signal shorted to a higher potential inside the charger high
- Charger low-voltage stage regulating too high medium
- Charger module software low
Symptoms
- MIL on (GM, after two trips in later model years)
- Charging may stop
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D45
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.