P0D40
Battery Charger A Input Voltage Sensor A Circuit High
P0D40 is the high-signal fault of the charger's input voltage sensor. GM's Volt charger module (2011 and 2014 tables) sets it when the measured AC peak exceeds 422 V for 160 of 200 ms and lights the MIL as a Type A fault; in the 2016 and 2019 Volt the controller reads a duty-cycle signal and fails it at 92 % and above or at a constant 0 %, Type B over two trips. Mitsubishi's 2022 Outlander PHEV reads a sensor voltage above 3.161 V, corresponding to more than 492 V, for 0.5 s as a short to power, stops charging and replaces the charger/DC-DC unit. Household and Level 2 supplies do not reach these values, so the sensor path or the signal line is normally to blame. P0D3F is the low counterpart.
Possible causes
- Voltage sensor signal shorted to supply inside the charger high
- Open duty-cycle signal line between charger and controller (2016-2019 Volt) medium
- Failed on-board charger medium
Symptoms
- AC charging is refused
- MIL on (GM)
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D40
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.