P0D2F
Drive Motor A Inverter Voltage Sensor A Circuit Low
P0D2F reports that the signal of inverter voltage sensor A for drive motor A sits at the bottom of its range, typical of an open circuit, a short to ground or no high voltage at all. In the 2018 Outlander PHEV Mitsubishi sets it in the front motor control unit when the sensor output stays below 0.5 V, equal to about 10 V on the bus, for 0.3 s while the propulsion system is active. The manual then checks the high-voltage fuse and the HV cabling before replacing the power drive unit, so a blown fuse or an open supply path can look like a sensor fault. The 2023 model uses 0.3 V at capacitor 1 for 0.16 s and lights the MIL. Expect the hybrid warning and loss of electric drive. The high side is P0D30.
Possible causes
- Blown high-voltage fuse or disconnected HV cable medium
- Voltage sensing in the power drive unit failed (open or short to ground) medium
- High-voltage battery delivers no voltage low
Symptoms
- MIL and hybrid system warning
- Vehicle not ready to drive or electric drive unavailable
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D2F
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.