P0D25
Battery Charger System Precharge Time Too Short
P0D25 is about the precharge of the charger's high-voltage bus, the short phase before the charging contactors close in which the bus capacitance is brought up to battery voltage through a limiting path. The code means this voltage arrived sooner than physically plausible. No manufacturer documents P0D25 publicly. GM describes the counterpart test for the charger bus under P0D26, with a window of 5 % around pack voltage, and the same principle for the main battery under P0C77, where the 2011 Volt flags a rise above 95 % within 50 ms. A rise that quick suggests a bypassed precharge resistor, a contactor that is welded or closes early, missing bus capacitance or a voltage sensor reporting wrong values. CARB requires charger faults that affect charging to be detected. Charging is normally refused.
Possible causes
- Precharge resistor bypassed or shorted medium
- Charging contactor welded or closing too early medium
- Bus or pack voltage sensor reporting wrong values low
- Bus capacitance much lower than expected low
Symptoms
- Charging refused at the start of a session
- Charging system warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D25
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.