P0D19
Battery Charging System A High Voltage Interlock Circuit Intermittent/Erratic
P0D19 covers a charging interlock loop that drops out and comes back, so the signal flips between valid and invalid within a short time. Loose terminals, a connector that is not fully latched, a chafing wire that only touches over bumps and vibration-sensitive solder joints are typical causes. No manufacturer documents P0D19 publicly. GM's Volt and ELR tables show the checks applied to the same loop, namely low and high limits on the sensed share of a 5 V reference, and a Ford patent explains why intermittent interlock contacts matter and how a loop can be arranged so a brief interruption does not cut propulsion. CARB requires plug-in vehicles to monitor charging components. Steady faults are P0D15–P0D18, the drive interlock intermittent code is P0A0E. Charging may stop without warning.
Possible causes
- Loose or spread terminal in an interlock connector high
- HV connector in the charging path not fully latched medium
- Chafed interlock wire making contact only under vibration low
Symptoms
- Charging stops unexpectedly
- Intermittent charging system warning
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0D19
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.