P0D17
Battery Charging System A High Voltage Interlock Circuit Low
P0D17 means the sensed voltage of the charging HVIL loop is too low. GM documents the check for the Chevrolet Volt (2011, 2014) and the Cadillac ELR: while the module sources 5 V into the loop, a sensed value under 30 % of the reference in two samples out of two at 12.5 ms sets the code as Type A, with the MIL on after one trip. A low reading suggests a path to ground or leakage somewhere in the loop wiring, or a fault in the measuring stage of the module. Because the test only runs with the source switched on, it typically shows up around charging. The interlock of battery and drive has its own code, P0A0C. P0D18 is the high counterpart, P0D15 the open loop. With an implausible loop the car refuses to charge.
Possible causes
- Interlock wire chafed and touching ground high
- Moisture or dirt in an interlock connector causing leakage medium
- Fault in the interlock source or measuring circuit of the control module low
Symptoms
- Malfunction indicator lamp after one trip (GM Type A)
- Charging refused
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0D17
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?