P0D16
Battery Charging System A High Voltage Interlock Circuit Performance
P0D16 flags a charging interlock loop that delivers a signal, just not the one expected – for example a reading that fails to follow when the module switches its test source on and off. No manufacturer documents P0D16 publicly. GM's Chevrolet Volt and Cadillac ELR show how such a loop is checked: the module feeds 5 V into the charging HVIL and compares the sensed level, as a share of the reference, against limits with the source on and off, which leads to P0D17 or P0D18. A Ford patent explains interlock loops built from shorting bars in connectors. Contact resistance in a connector, a plug inserted only partway and corrosion are typical. Open loops are P0D15, sporadic faults P0D19, the drive-side counterpart P0A0B. Charging is usually blocked.
Possible causes
- Contact resistance or corrosion in an interlock connector high
- HV connector in the charging path inserted only partway medium
- Fault in the module's interlock source or measuring stage low
Symptoms
- Charging refused
- Charging system warning
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0D16
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.