P0D15
Battery Charging System A High Voltage Interlock Circuit/Open
P0D15 reports an open high-voltage interlock loop in charging system A. This low-voltage loop runs through the connectors and covers of the charging path – inlet, charger and their HV leads – and breaks as soon as one of them is unplugged, so the module can keep that path de-energised. It is separate from the interlock of battery and drive, which uses P0A0A ff. Volvo stores P0D1513 in the on-board charger of the 2021–2023 XC40 Recharge when AC charging fails; bulletin TJ 36522 blames catches on the AC HV connector between inlet and charger that were not fully closed at the plant and has the connector reseated and latched. GM's Volt and ELR monitor such a charging loop with a 5 V source, and a Ford patent describes interlock shorting bars in connectors. Other loop faults are P0D16–P0D19.
Possible causes
- HV connector in the charging path not fully seated or latched (Volvo XC40) high
- Broken interlock wire or pushed-back terminal medium
- Missing or loose cover on a charging component low
Symptoms
- AC charging not possible
- Charge inlet light indicates a fault
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0D15
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?