Battery Charging System Negative Contactor A Control Circuit High
P0D14 is set when the control line of negative charging contactor A reads too high, for example through a short to the 12 V supply or a driver stage that will not switch off. That can keep the coil energised and the contactor closed without a command, so the module blocks charging. No manufacturer documents P0D14 publicly; on the Volt and ELR GM counts a short to power under P0D11 and detects it when the off-state output stays close to supply voltage. CARB requires plug-in vehicles to monitor charging components. Chafed or crossed wiring and a failed driver are the main causes. The low case is P0D13, a welded contactor P0D0F, the positive side P0D0D. Repairs belong in the hands of high-voltage trained staff.
Possible causes
- Control wire shorted to a supply voltage high
- Driver stage in the control module stuck on medium
- Open ground return of the coil letting the line float high low
Symptoms
- Charging blocked
- Charging or high-voltage system warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended