P0D13
Battery Charging System Negative Contactor A Control Circuit Low
P0D13 means the control line of negative charging contactor A reads too low, which points to a short to ground or a driver output held down. The coil then receives no current, or too little, and the contactor stays open. No manufacturer documents P0D13 publicly; GM notes that its P0D11 test for this contactor on the Volt and ELR cannot detect a short to ground, and CARB requires plug-in vehicles to monitor charging components. Typical causes are a wire chafed against the body or battery housing and moisture inside a connector. P0D14 is the high counterpart, P0D11 the open circuit, P0D0C the same fault on the positive side. In practice the vehicle refuses to charge.
Possible causes
- Control wire chafed through and shorted to ground high
- Moisture in a connector creating a path to ground medium
- Shorted contactor coil low
Symptoms
- Vehicle refuses to charge
- Charging system warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D13
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?