P0D10
Battery Charging System Negative Contactor A Stuck Open
P0D10 means negative charging contactor A does not close when told to, so the charging path never gets its return line and the session fails. Ford names it in the BECM of the 2021–2023 Mustang Mach-E next to main-contactor codes; the bulletins (23-2020, 23-2257) replace the high-voltage battery junction box and update the BECM. GM's preliminary PIT6083 for the 2024 Lyriq links P0D09 and P0D10 to very long charging sessions and advises disconnecting the cord once a day for 20 minutes or more until new software arrives. Stellantis lists both codes for the Wagoneer S and Charger Daytona, where a no-start can follow, and handles them with BPCM updates. Welding on this side is P0D0F, the control circuit P0D11, the positive counterpart P0D09. Expect charging to stop.
Possible causes
- Faulty high-voltage battery junction box with the charging contactors (Ford Mach-E) high
- Battery module software needing an update (GM Lyriq, Stellantis) medium
- Contactor failing to close or burnt contacts medium
Symptoms
- Charging does not start or stops
- Malfunction indicator lamp and high-voltage service message
- Vehicle may not start (Lyriq, Stellantis)
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D10
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?