P0D0B
Battery Charging System Positive Contactor A Control Circuit Range/Performance
P0D0B reports that the control circuit of positive charging contactor A works electrically but does not behave plausibly – coil current or line voltage outside the window expected for the commanded state, or a response that comes too slowly. No manufacturer documents P0D0B publicly. The nearest documented test is GM's P0D0A on the Chevrolet Volt, which matches commanded and actual driver state and judges coil current, and CARB requires plug-in vehicles to check charging components for circuit and rationality faults. Typical triggers are contact resistance in connectors, a coil whose resistance has drifted, or a weakening driver stage. Opens are P0D0A, low and high signals P0D0C/P0D0D, mechanical sticking P0D08/P0D09. Charging may work only now and then or be refused.
Possible causes
- Contact resistance or corrosion in the control circuit connectors high
- Contactor coil with changed resistance medium
- Weakening driver stage in the control module low
Symptoms
- Charging sessions fail sporadically
- Stored code, possibly with a charging system warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D0B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.