P0D07
Battery Charging System Positive Contactor A Circuit
P0D07 is the general circuit code for positive contactor A of the charging system, the switch that joins the plus side of a charging path to the traction battery. Depending on the design this path comes from the DC fast-charge inlet or from the on-board charger; the Chevrolet Volt, for instance, places charging contactors between charger and pack. The code stands for an electrical fault in that contactor branch which fits no more specific case. No manufacturer documents P0D07 publicly; a GM patent describes judging such contactors by their coil current, and CARB requires plug-in vehicles to monitor charging components. Welded or non-closing contacts are P0D08/P0D09, driver faults P0D0A–P0D0D, the main pack contactors P0AA0 ff. Usually charging is blocked while driving still works.
Possible causes
- Contactor coil open or shorted medium
- Damaged wiring or corroded connector in the contactor branch medium
- Fault in the module that drives and monitors the contactor low
Symptoms
- Charging not possible or aborted
- Charging system warning in the instrument cluster
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D07
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.