P0D06
Control Pilot Charging Ventilation Switch Stuck On
Stuck On means the ventilation switch remains closed when it should be open, so the pilot is held near 3 V and the station reads a permanent demand for charging with ventilation. Stations that cannot provide ventilation do not supply power in that state, which in practice stops charging altogether. Likely causes are a welded or sticking switch, a short across the 270 Ω branch, or a module output that no longer releases. No manufacturer documents this code publicly; GM's Chevrolet Volt checks the same switch through P0D01 by the pilot level it causes in a self-test, and Mercedes-Benz documents the matching failure of charging switch A as P0CFE00 (switch not opening, cured by software). The counterpart is P0D05, circuit faults are P0D00 to P0D03. The car is detected at the station but does not charge.
Possible causes
- Ventilation switch contacts welded or sticking closed medium
- Short across the ventilation resistor branch medium
- Module output or software holding the switch on low
Symptoms
- Charging station does not supply power
- Charging error message after plugging in
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0D06