Hybrid/EV Charging System Voltage Out Of Range
Charging system detects mains voltage outside acceptable range during AC charging, preventing safe charge initiation.
SystemPowertrain
Typegeneric / SAE
GroupP0
Range / numberD / 02
Possible causes
- EVSE delivering wrong voltage high
- Mains supply unstable medium
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 100–1500 €
- Estimated time: 0.5–5 h
- Component: on board charger
- Component: charge port
- Component: external evse
- MIL / check engine light