P0CF8
Control Pilot Charging Switch A Circuit/Open
On the vehicle side the pilot is loaded permanently by about 2.7 kΩ, which drops the station's +12 V to roughly 9 V once a cable is connected. To ask for energy the vehicle closes charging switch A, often called S2, which adds a 1.3 kΩ branch and brings the level to about 6 V, the state in which the station closes its contactors. P0CF8 reports that the control circuit of this switch is open, so the module cannot operate it. No manufacturer documents this code publicly; GM tests the same switch on the Chevrolet Volt only for plausibility (P0CF9, normalized pilot voltage 0.14-0.28 in a self-test), and CARB requires plug-in vehicles to monitor charging system function. Shorts are P0CFA/P0CFB, a switch that will not close is P0CFD. Expect a car the station recognises that still never starts charging.
Possible causes
- Open control wire or loose connector between module and charging switch medium
- Charging switch or its 1.3 kΩ branch open inside the module or inlet electronics medium
- Failed driver stage in the charging control module low
Symptoms
- Station detects the vehicle but charging never begins
- Charging fault message after plugging in
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0CF8
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.