P0CDC
Drive Motor A Position Sensor Circuit C Low
P0CDC reports that circuit C of the rotor position sensor on drive motor A reads below its permitted window. Typical reasons are a short to ground, a short between windings or a low-resistance path through moisture in the connector. For circuits A and B GM shows how such a test works: the motor control processor compares the sensed resolver voltage with a threshold and sets a Type B code when it stays out of range for 0.25 s within a 0.375 s window (P0C52, P0C5C). No manufacturer publicly documents the circuit C version, and what that circuit carries is not published. As soon as the angle signal becomes unreliable, the inverter reduces or stops electric drive torque, and regeneration may be cut as well. Check plug and harness to the inverter before replacing parts. The high fault is P0CDD.
Possible causes
- Circuit C wire shorted to ground or to another resolver wire high
- Moisture or corrosion in the resolver connector medium
- Resolver winding internally shorted low
Symptoms
- Hybrid system warning and MIL
- Electric drive limited, engine runs instead
- Reduced or no regenerative braking
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0CDC
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.