Charge Port Door A Open Request Switch Circuit High
With P0CCA the control module sees the charge flap A open request switch signal above its highest valid level. Depending on the circuit, a wire shorted to battery voltage or an interrupted ground or switch path pushes the reading up. GM's Volt monitor from 2011 onward flags it when more than 94.5 percent of the reference is measured in six of eight samples, then stores it as a Type B code with the lamp after two trips; the 2013 table stretches the sample spacing to 500 ms. Low readings below 22.9 percent go to P0CC9 instead, and an invalid middle value to P0CC7. Since a high reading usually looks like a button that is never pressed, the typical complaint is a charge flap that cannot be opened from the switch.
Possible causes
- Signal wire shorted to a 12 V supply high
- Interrupted ground or switch return path medium
- Pin pushed back in the connector medium
Symptoms
- Charge flap cannot be opened with the button
- Warning lamp after two trips (GM Volt)
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0CCA
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?