P0CA0
14 Volt Power Module Current Sensor B Circuit Intermittent
P0CA0 covers short dropouts or spikes in the signal of current sensor B, the output-side sensor of the 14 V power module (DC/DC converter) in GM's numbering. Between the events the reading looks normal, which separates it from the hard low and high faults P0C9E and P0C9F. No manufacturer documents P0CA0 publicly; GM's eAssist table only lists fixed limits for this sensor, below 2 A and above 123 A, each judged over 1.5 s in 2 s, and the cross-check P0CC5. CARB paragraph (e)(15.3.1) still expects such inputs to be monitored without pause. Vibration, a loose module connector, corroded grounds or poor 12 V cable connections are the first things to inspect; freeze-frame data helps to catch the moment.
Possible causes
- Loose or fretting connector at the power module high
- Corroded ground or 12 V output connection medium
- Current sensor B failing intermittently inside the module low
Symptoms
- Warning lamp that comes and goes
- Occasional dim lights or voltage messages
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0CA0
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?