P0C9B
Hybrid/EV Battery Temperature Sensor L Circuit Intermittent/Erratic
P0C9B covers a sensor L signal that jitters. GM's tables 18OBDG02 and 19OBDG02 integrate the absolute sample-to-sample changes over ten readings spaced 100 ms apart; when the integral exceeds 10, that window fails, and 4 failures within 5 windows store the code, classed Type B. Supply must exceed 10.2 V and communication with the battery interface module must be present. Because the value may never leave its valid band, P0C99 and P0C9A can stay silent. Mitsubishi does not use this code. A fretting pin, a cracked conductor or a loose board ground are typical, and the fault may vanish between drives, so freeze-frame data and a wiggle test help to find it.
Possible causes
- Fretting pin in the sensor L connector high
- Cracked conductor in the sensor L lead medium
- Loose ground on the cell monitoring board low
Symptoms
- Warning lamp that may switch off again by itself
- Erratic sensor L value in live data
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0C9B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.