Powertrain
generic / SAE
P0C6C
Generator Position Sensor Circuit B Circuit High
The generator position sensor channel B reports a circuit high fault. Wiring faults of this kind typically come from chafing, water ingress at connector seals, or pin push-back — a wiggle test on the harness while the code is active often confirms the location.
SystemPowertrain
Typegeneric / SAE
GroupP0
Range / numberC / 6C
Possible causes
- Signal wire shorted to B+ high
- Open sensor medium
- Connector pins corroded - high contact resistance low
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
- Estimated cost: 400–2500 €
- Estimated time: 2–8 h
- Component: generator position sensor b
- Component: wiring harness
- Component: hybrid control module
- MIL / check engine light
- limp mode possible
Sources
References
sae:J2012