P0C5B
Drive Motor A Position Sensor Circuit B Range/Performance
P0C5B is set when the second resolver winding of motor A (Circuit B) stays within its electrical limits yet carries a signal that does not make sense next to the first winding. Bentley added it in revision 3 of bulletin 2080242 for the Continental GT, GTC and Flying Spur hybrids: P0C5B00 now appears alongside P0C5100 and P0A4000, which shows that both windings lose plausibility at once when the shared connection is poor. The repair path is the same, measured value logs, inspection of the 8-pin and 32-pin plugs for pin drag and corrosion, replacement of a 90-degree connector after approval, then basic settings. No threshold is published. P0C5C to P0C5E are the low, high and sporadic Circuit B faults.
Possible causes
- Insufficient terminal grip at the sensor or power electronics connector high
- Faulty 90-degree connector on affected Bentley hybrids (TPI 2080242/3) medium
- Corrosion, oil or moisture in the resolver plugs medium
Symptoms
- Drive system fault shown in the cluster
- Electric drive mode not available
- Usually stored together with P0C51 and P0A40
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0C5B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.