P0C4D
Hybrid/EV Battery Pack Coolant Pump A Supply Voltage Circuit High
P0C4D is the counterpart to P0C4C: the voltage measured on the supply of battery coolant pump A is higher than the controller allows. That can come from a feed wire shorted to another, more highly loaded circuit, from a relay that stays closed when the pump should be off, or from an overall excessive on-board voltage, for example a faulty DC/DC converter. No manufacturer documents P0C4D publicly. Ford's bulletins for the 2020 Escape, Explorer and Aviator hybrids name the sibling P0C4B for the open supply, and Bentley describes the feed of the same pump with fuse and relay for 2025–2026 hybrids. CARB requires the electrical components of battery thermal management to be monitored. If several modules log overvoltage at once, the 12 V supply is the more likely culprit than the pump circuit.
Possible causes
- Supply wire shorted to another voltage-carrying circuit medium
- Pump relay sticking closed medium
- Excessive 12 V system voltage from a faulty DC/DC converter low
Symptoms
- MIL or hybrid or EV warning
- Coolant pump running although the system is switched off
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0C4D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.