P0C41
DC/DC Converter Temperature Sensor B Intermittent/Erratic
P0C41 concerns a reading from DC/DC converter temperature sensor B that jumps or briefly drops out while it mostly remains inside the valid range. A converter heat sink changes temperature slowly, so abrupt steps indicate a signal problem rather than real heating. No manufacturer documents P0C41 publicly. GM's 2019 hybrid tables show the usual method on the battery coolant thermistor: the controller adds the absolute differences of ten consecutive 100 ms samples and counts a failure when the sum exceeds 64 °C, setting the code after 4 s within a 5 s window. CARB requires hybrid component inputs to be monitored for such faults. Typical culprits are a loose terminal, moisture or vibration damage. Unlike P0C3F and P0C40, the fault can disappear between checks.
Possible causes
- Loose terminal or moisture at the converter connector high
- Harness chafed or cracked by vibration medium
- Intermittent contact inside the converter low
Symptoms
- Hybrid or EV warning that comes and goes
- Short interruptions of 12 V charging
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0C41
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?