P0C0E
Drive Motor B Inverter Power Supply Circuit/Open
P0C0E is the motor B counterpart of P0C0B: the inverter for the second motor has lost the supply of its gate-drive board. GM documents it on the Volt and the two-mode trucks. The IGBT module reports a bias fault through its status line when the supply of phase A, B or C fails. The 2011 Volt checks with high voltage above 100 V, the 2012 trucks with run/crank voltage between 9.5 and 18 V, both after one count, Type A. The 2016 Volt needs 0.002 s of fault in a 0.024 s window, the 2018 table 0.02 s, the 2019 table 0.168 s, always Type A, one trip. P0C0F and P0C10 cover low and high supply. Motor B can no longer be driven, so propulsion is reduced.
Possible causes
- Failed gate-drive power supply inside the motor B inverter high
- Weak 12 V feed, blown fuse or poor ground at the inverter control board medium
- Loose or corroded low-voltage connector at the power inverter module low
Symptoms
- Malfunction indicator lamp after one drive
- Reduced propulsion message, motor B unavailable
- Engine runs continuously instead of electric driving
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0C0E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- gsi.ext.gm.com/gmspo/mode6/pdf/2011/11OBDG01 HYBRID Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2012/12OBDG06 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2016/16OBDG01 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2018/18OBDG02 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2019/19OBDG01 Hybrid Diagnostics.pdf