P0C08
Drive Motor B Phase U-V-W Circuit/Open
P0C08 is the open-phase check for drive motor B, the motor B twin of P0C05. GM runs it on the 2011 Volt and the 2012 two-mode trucks: each phase is checked as the rotor passes its axis, and a phase axis current below 9 A while at least 23 A is commanded, with the rotor within 30 degrees and over 35 V on the inverter, counts as a miss. Around 200 failed samples set it, Type A, one trip. Later GM tables up to 2016 keep the same logic. GM's eAssist has only one machine and no P0C08. The usual causes are a loose three-phase terminal, an open stator winding or an inverter stage that does not conduct. Motor B then delivers no torque, the MIL lights and drive power is reduced.
Possible causes
- Loose or open three-phase terminal between inverter and motor B high
- Open stator winding in drive motor B medium
- Inverter stage for motor B not conducting medium
Symptoms
- Malfunction indicator lamp after one drive
- Reduced propulsion power
- Engine running more often than usual
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended