P0C07
Drive Motor A Phase U-V-W Circuit High
P0C07 is the high member of the drive motor A phase circuit group: a U, V or W phase line reads higher than it should, most likely through a short to the positive high-voltage rail or a power switch that stays on. Its siblings are P0C05 for an open phase and P0C06 for a phase pulled low. No manufacturer documents P0C07 publicly; among these three, GM uses only P0C05, which watches for missing phase current. CARB requires circuit monitoring of hybrid input and output components. Because a stuck high phase drives uncontrolled current, the inverter normally disables motor A at once. The driver sees a warning lamp and loses some or all electric propulsion until the shorted part is replaced.
Possible causes
- Shorted high-side power switch in the motor A inverter medium
- Phase cable shorted to the positive high-voltage path medium
- Faulty gate driver holding a switch on low
Symptoms
- Immediate shutdown of electric drive with warning lamp
- Reduced performance or engine-only operation
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0C07
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.