P0C04
Drive Motor B Current High
P0C04 is the overcurrent check of drive motor B and protects the IGBTs of its inverter. GM flags it when the highest phase current exceeds 725 A on the 2011 Volt or 600 A on the 2012 two-mode trucks and in the 2016 to 2019 hybrid tables; the newer tables also fail a d-axis current below a stator-temperature curve of roughly -556 to -315 A. Fast and slow counters cover sudden and intermittent peaks, Type A, one trip. Stellantis names P0C04 with P0C01 on the 2026 Jeep Wagoneer S and Cherokee: cross-threaded or loose bolts on the three-phase cables between transmission and drive motor power inverter, checked by resistance against a 29 to 32 milliohm window. The car goes into limp mode with the MIL on.
Possible causes
- Cross-threaded or loose three-phase cable bolts with metal debris (Stellantis S2608000006) high
- Shorted or damaged stator winding of motor B medium
- Failing power switch or current measurement in the motor B inverter low
Symptoms
- Limp mode with red wrench or malfunction lamp
- Sudden loss of electric drive power
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0C04
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- gsi.ext.gm.com/gmspo/mode6/pdf/2011/11OBDG01 HYBRID Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2012/12OBDG06 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2018/18OBDG02 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2019/19OBDG01 Hybrid Diagnostics.pdf
- static.nhtsa.gov/odi/tsbs/2026/MC-11029775-0001.pdf