P0BEF
Drive Motor A Phase W Current Sensor Circuit Low
P0BEF indicates that the phase W current sensor of the motor A inverter delivers a signal below its valid range. GM's limits: below -700 A for 0.05 of 0.1 s (2016 tables) or 0.1 of 0.15 s (2019), Type A; below -800 A, Type A, on the 2011 Volt; below -700 A, Type B, on the 2012 two-mode trucks; below -440 A, Type B, two trips, in the BAS Plus (eAssist) table. These readings lie far outside real phase currents, so a sensor output stuck near ground, a failed sensor or a supply fault is the likely cause. In the eAssist system this fault puts current control into a mode that ignores the sensors, and it disables the U-V-W correlation check P0BFD, so motor A runs with reduced output.
Possible causes
- Failed phase W current sensor inside the inverter high
- Sensor signal or supply pulled to ground on the sensor board medium
- Poor contact at an internal or external inverter connector low
Symptoms
- Malfunction indicator lamp and hybrid warning
- Reduced power or no assist from drive motor A
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended