P0BE3
Drive Motor Inverter Temperature Sensor F Circuit High
P0BE3 is the high-signal fault of inverter temperature sensor F, GM's phase W thermistor in the motor B inverter. With an NTC element and pull-up, an open circuit or a sensor that has lost ground drives the voltage up, which the controller reads as an implausibly cold inverter. GM only judges this after the inverter has worked for at least 90 s at 20 Nm or more: below -50 °C for 2.625 of 3.65 s sets Type B, two trips (2016 and 2018 tables), or Type A for 6.25 of 8.75 s (2019). The 2011 Volt uses below -58 °C (Type A), the 2012 and 2013 two-mode trucks below -40 °C (Type B). Expect limited output from motor B until the circuit is repaired.
Possible causes
- Open thermistor or broken connection inside the power inverter module high
- Loose or corroded connector at the inverter medium
- Lost sensor reference ground on the sensing board low
Symptoms
- Malfunction indicator lamp and hybrid warning
- Reduced power from drive motor B once warmed up
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0BE3
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- gsi.ext.gm.com/gmspo/mode6/pdf/2016/16OBDG02 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2018/18OBDG02 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2019/19OBDG01 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2011/11OBDG01 HYBRID Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2013/13OBDG06 Hybrid Diagnostics.pdf