P0BE2
Drive Motor Inverter Temperature Sensor F Circuit Low
P0BE2 is set when the voltage from inverter temperature sensor F, the phase W thermistor in GM's motor B inverter, drops below the valid window. Because GM pairs an NTC element with a pull-up resistor, a short to ground is converted into a temperature far above anything the inverter can survive. Limits found in GM's tables: more than 170 °C for 2.5 of 3.5 s, Type B, two trips (2016 and 2018); more than 159 °C for 6.25 of 8.75 s, Type A (2019); more than 130 °C, Type A (2011 Volt); more than 125 °C, Type B (2012 and 2013 two-mode trucks). Genuine overheating of this phase has its own code, P0C16. The thermistor is part of the inverter, so it is rarely replaced on its own.
Possible causes
- Shorted thermistor or signal line inside the power inverter module high
- Signal shorted to ground in external wiring, where the design has any medium
- Moisture or coolant inside the inverter housing low
Symptoms
- Malfunction indicator lamp and hybrid warning
- Power of drive motor B strongly limited
- Engine runs more often in hybrid operation
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0BE2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.
Sources
- gsi.ext.gm.com/gmspo/mode6/pdf/2016/16OBDG02 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2018/18OBDG02 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2019/19OBDG01 Hybrid Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2011/11OBDG01 HYBRID Diagnostics.pdf
- gsi.ext.gm.com/gmspo/mode6/pdf/2012/12OBDG06 Hybrid Diagnostics.pdf