Hybrid/EV Battery Pack Cooling Fan Supply Voltage Circuit High
P0BC1 flags voltage on the battery fan feed when there should be none, or more than expected. GM documents it for the battery pack control module of its Two-Mode hybrid SUVs and pickups (Tahoe, Yukon, Escalade, Silverado, Sierra; 2012 and 2013 tables) as a welded fan relay: with the fan commanded off, a fan monitor voltage of at least 0.9 V in 10 of 20 samples at 100 ms sets it, provided the 12 V system is between 9 and 18 V and no fan circuit code (P0A81) is active. It is Type B, MIL after two trips. A stuck relay keeps the fan running with the vehicle off and drains the 12 V battery. The open and low cases are P0BBF and P0BC0; a fan that keeps turning without this fault is P0A83.
Possible causes
- Fan relay contacts welded closed high
- Fan feed shorted to a constant battery voltage wire medium
- Relay control output in the module stuck on low
Symptoms
- MIL on after two trips
- Battery fan keeps running after the vehicle is switched off
- Discharged 12 V battery after standing
Inspection / repair
- Difficulty: easy
- DIY: possible
What Pro shows you for P0BC1
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?