P0BB1
Hybrid/EV Battery Voltage Sense X Circuit High
P0BB1 means the battery controller sees too much voltage on sense X. In GM's 2019 battery energy control module the threshold is 4.8 V or more, held for 1.4 s within a 2 s window, and the code is Type A, so the MIL comes on in the first trip. The 16OBDG02 programme allows up to 4.90 V and needs 14 failing samples out of 18, while the eAssist battery treats anything above 4.65 V in seven of ten samples as a Type B fault. These tests are suppressed while an open sense line or a lost communication with the cell monitoring slave is active. A real cell at that voltage would be dangerously overcharged, so a wiring fault towards the neighbour cell or a defective input is the more frequent finding.
Possible causes
- Sense lead X shorted to the next higher cell high
- Measuring input X drifting high medium
- Cell X genuinely over voltage low
Symptoms
- MIL in the first trip
- Charging and regenerative braking disabled
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0BB1
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.