P0BAE
Hybrid/EV Battery Voltage Sense X Circuit
Channel X, number twenty-four, starts with P0BAE, the open-lead code. The first-generation Volt of 2011 already detected it through several cases: two neighbouring readings more than 1 V apart, a busbar sense voltage above 0.7 V combined with an implausible cell voltage, or adjacent cells differing by more than 0.5 V on a shared supply line. GM's later 16OBDG02 programme measures the sense line resistance directly and fails it above 30.00 in seven of nine samples, Type A; the unit is not printed. In the 2019 battery energy control module the familiar 1.3 V and 36 mV criteria apply with 0.8 s in 1.6 s. Whichever method is used, the controller loses sight of one cell and normally restricts the battery.
Possible causes
- Sense lead X broken or disconnected high
- Loose busbar fastener at the X sensing point medium
- Sense harness X damaged during earlier battery work low
Symptoms
- MIL and service message for the high-voltage system
- Vehicle may stay out of ready mode
- Charging stops early
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0BAE
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.