P0BA9
Hybrid/EV Battery Voltage Sense W Circuit
P0BA9 opens the W group, the twenty-third cell voltage channel, and flags a sense lead that is open or badly connected. GM's 2019 battery energy control module checks seven cases, ranging from a reading under 36 mV while the balancing gate of that cell is switched on to at least 1.3 V between neighbouring cells and splice voltages above 0.1 V or 0.5 V at busbar joints; 0.8 s of failure within 1.6 s sets it as Type A. The 2016 Volt module uses a 0.6 s window instead. GM's eAssist mild hybrid needs readings under 1.4 V on lines N and N-1 plus a change of more than 0.5 V within 200 ms in seven of ten samples, Type B. With the lead lost, the cell behind it can neither be balanced nor protected.
Possible causes
- Broken, chafed or unplugged sense lead W high
- High-resistance busbar or splice joint at channel W medium
- Failed input on the cell monitoring board for W low
Symptoms
- MIL with hybrid or EV system warning
- Reduced propulsion power or no ready mode
- Charging interrupted or refused
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0BA9
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.